Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 80 of 126 April 19, 2010
(7) UPPER BODY COMPARTMENTS
The forward transverse compartment shall be 90.0" wide x 26.0" x 23.5" deep and shall include a removable cover to
allow access to the specified DOT bottles stored in the transverse area of compartment S1/C1. There shall be six (6)
compartments parallel to the sides of the body, three (3) on each side. Each of these compartments shall be 76.0" wide x
26.0" x 23.5" deep. The side compartments shall be open under each door sill to allow for long equipment. Each
compartment shall be integral with the body construction, and will not be bolted or add-on modules. The outside walls of
each compartment will be double walled to prevent equipment from denting the outside painted surface.
Each compartment shall have a lift-up type compartment door hinged on the outboard side. Each door shall be fabricated
from 3/16" aluminum tread plate. Each door shall have two (2) pneumatic type cylinders, one (1) at each end, attached to
cast aluminum brackets mounted to the interior surface of the door to hold the door in both the opened and closed
positions. Each door shall be mounted using 16" long, equally spaced, 14 gauge stainless steel hinges, with 1/4"
stainless steel pin. A polyester barrier film gasket shall be placed between stainless steel hinge and the body mounting
surface as necessary to prevent corrosion caused by dissimilar metals.
Each compartment door shall overlap a 2" vertical lip on the body roof to prevent entry of moisture and sealed with
automotive type rubber molding to provide a weather resistant seal.
Each compartment shall have a horizontally mounted OnScene Solutions LED Night Stik on the underside of the door.
The light will be automatically activated by a gravity-driven, sealed, ball-style tilt switch mounted to one of the cast
aluminum pneumatic cylinder mounting brackets and also wired to the NFPA required hazard warning light in cab.
Two (2) TNT model ET-4.0, 4 HP, 240 VAC hydraulic power unit(s) capable of operating two (2) TNT rescue tools
simultaneously shall be provided int the transverse upper body compartment, one (1) per side. Two (2) 240 VAC
twist lock receptacle(s) shall be provided, one (1) per power unit. Two (2) power switch(es) shall be provided, one
(1) under the rescue bumper compartment lid to turn the streetside power unit ON/OFF, and one (1) on the
forward wall of compartment C4 to turn the curbside power unit ON/OFF.
Each roof compartment door shall have a chrome 7" handle bolted to center of each door.
SIDE ROOF COMPARTMENT - SHELF TRAC
There shall be one (1) roof compartment(s) provided with horizontally mounted Shelf Trac on front and rear walls for
vertical partition installation.
ROOF COMPARTMENT - VERTICAL PARTITION
There shall be six (6) vertical partition(s) provided in the roof compartment(s). The partitions shall be designed for holding
equipment in place during travel. Each partition shall be fabricated from 3/16" smooth aluminum and bolted to specified
Shelf Trac for ease of adjustment.
UPPER BODY WALKWAY
A 34" wide, upper body walkway shall be provided at the center of body and recessed into the roof structure. The walkway
shall be finished with NFPA compliant 3/16" aluminum tread plate with continuously welded seams to prevent moisture
penetration into apparatus body. Drains shall be installed at front of walkway to allow water to drain to the ground
through flexible drain hose.