Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 1 of 126 April 19, 2010
INTERNET IN-PROCESS SITE ............................................................................................................................................ 10
VEHICLE STABILITY SUPPLIED WITH CAB/CHASSIS ..................................................................................................... 10
ROADABILITY....................................................................................................................................................................... 10
SERVICEABILITY ................................................................................................................................................................. 10
CONSTRUCTION DOCUMENTATION ................................................................................................................................ 11
OPERATIONS AND SERVICE DOCUMENTATION ............................................................................................................ 12
NFPA REQUIRED DOCUMENTATION FORMAT - CD-ROM ............................................................................................. 12
CARRYING CAPACITY ........................................................................................................................................................ 13
TESTING ............................................................................................................................................................................... 14
ROAD TEST .......................................................................................................................................................................... 14
LOW VOLTAGE - ELECTRICAL SYSTEM PERFORMANCE TEST ................................................................................... 14
TEST SEQUENCE ................................................................................................................................................................ 14
1. RESERVE CAPACITY TEST ........................................................................................................................................... 14
2. ALTERNATOR PERFORMANCE TEST .......................................................................................................................... 15
TEST AT IDLE....................................................................................................................................................................... 15
TEST AT FULL LOAD ........................................................................................................................................................... 15
3. LOW VOLTAGE ALARM TEST ....................................................................................................................................... 15
LOW VOLTAGE - ELECTRICAL SYSTEM PERFORMANCE TEST ................................................................................... 15
DOCUMENTATION .............................................................................................................................................................. 15
UL 120/240 VAC CERTIFICATION ...................................................................................................................................... 16
DOCUMENTATION .............................................................................................................................................................. 16
DIELECTRIC VOLTAGE WITHSTAND TEST ...................................................................................................................... 17
WARRANTY .......................................................................................................................................................................... 17
GENERAL LIMITED WARRANTY - ONE (1) YEAR ............................................................................................................. 17
LOW VOLTAGE ELECTRICAL WARRANTY - FIVE (5) YEARS ......................................................................................... 17
STRUCTURAL WARRANTY - TEN (10) YEARS ................................................................................................................. 18
PAINT LIMITED WARRANTY - TEN (10) YEARS ................................................................................................................ 18
CONSTRUCTION PERIOD .................................................................................................................................................. 18
OVERALL HEIGHT ............................................................................................................................................................... 18
OVERALL LENGTH .............................................................................................................................................................. 18
PRE-CONSTRUCTION CONFERENCE .............................................................................................................................. 18
PRE-PAINT CONFERENCE ................................................................................................................................................. 18
FINAL INSPECTION CONFERENCE ................................................................................................................................... 18
DELIVERY AND DEMONSTRATION ................................................................................................................................... 19
90% PREPAYMENT DISCOUNT ......................................................................................................................................... 19
TRADE-IN ............................................................................................................................................................................. 19
MODEL .................................................................................................................................................................................. 20
MODEL YEAR ....................................................................................................................................................................... 20
COUNTRY OF SERVICE ...................................................................................................................................................... 20
APPARATUS TYPE .............................................................................................................................................................. 20
VEHICLE TYPE..................................................................................................................................................................... 20
AXLE CONFIGURATION ...................................................................................................................................................... 20
GROSS AXLE WEIGHT RATINGS FRONT ......................................................................................................................... 20
GROSS AXLE WEIGHT RATINGS REAR ........................................................................................................................... 20
CAB STYLE........................................................................................................................................................................... 20
CAB FRONT FASCIA ........................................................................................................................................................... 22
FRONT GRILLE .................................................................................................................................................................... 22
CAB PAINT EXTERIOR ........................................................................................................................................................ 22
CAB PAINT MANUFACTURER ............................................................................................................................................ 22
CAB PAINT PRIMARY/LOWER COLOR .............................................................................................................................. 22
CAB PAINT WARRANTY ...................................................................................................................................................... 23
CAB ENGINE TUNNEL ......................................................................................................................................................... 23
CAB ENTRY DOORS ........................................................................................................................................................... 23
CAB ENTRY DOOR TYPE ................................................................................................................................................... 23
Przeglądanie stron 0
1 2 3 4 5 6 ... 125 126

Podsumowanie treści

Strona 1 - Heavy Rescue

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 1 of 126 April 19, 2010 INTERNET IN-PROCESS SITE ...

Strona 2

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 10 of 126 April 19, 2010 INTERNET IN-PROCESS SITE T

Strona 3

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 100 of 126 April 19, 2010 HEAVY DUTY 100% EXTENSION

Strona 4

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 101 of 126 April 19, 2010 COMPARTMENT LIGHTING Each

Strona 5

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 102 of 126 April 19, 2010 The rewind control or cra

Strona 6

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 103 of 126 April 19, 2010 LOW PRESSURE AIR HOSE REEL

Strona 7

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 104 of 126 April 19, 2010 If the discharge end of ho

Strona 8

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 105 of 126 April 19, 2010 BREATHING AIR STORAGE SYST

Strona 9

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 106 of 126 April 19, 2010 BREATHING AIR SYSTEM TESTI

Strona 10

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 107 of 126 April 19, 2010 SCBA FILL ENCLOSURE AND AC

Strona 11

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 108 of 126 April 19, 2010 LOW VOLTAGE ELECTRICAL SYS

Strona 12

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 109 of 126 April 19, 2010 Circuits shall be provided

Strona 13

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 11 of 126 April 19, 2010 CONSTRUCTION DOCUMENTATION

Strona 14

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 110 of 126 April 19, 2010 A voltmeter shall be mount

Strona 15

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 111 of 126 April 19, 2010 Electronic control systems

Strona 16

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 112 of 126 April 19, 2010 TAIL LIGHTS Rear body ta

Strona 17

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 113 of 126 April 19, 2010 FIRECOM INTERCOM SYSTEM T

Strona 18

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 114 of 126 April 19, 2010 ZONE A - FRONT WARNING LIG

Strona 19

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 115 of 126 April 19, 2010 ZONE C - REAR WARNING LIGH

Strona 20

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 116 of 126 April 19, 2010 ZONE C - REAR WARNING LIGH

Strona 21

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 117 of 126 April 19, 2010 GENERATOR MOUNTING The

Strona 22

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 118 of 126 April 19, 2010 LOADCENTER The loadcent

Strona 23

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 119 of 126 April 19, 2010 Location Ratings Any equi

Strona 24

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 12 of 126 April 19, 2010 OPERATIONS AND SERVICE DOC

Strona 25

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 120 of 126 April 19, 2010 Power Source Rating For p

Strona 26

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 121 of 126 April 19, 2010 Power Supply Assembly The

Strona 27

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 122 of 126 April 19, 2010 Where the power source is

Strona 28

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 123 of 126 April 19, 2010 Wiring System Components

Strona 29

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 124 of 126 April 19, 2010 Wiring Schematics An &quo

Strona 30

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 125 of 126 April 19, 2010 REAR TRIPOD SCENE LIGHTS

Strona 31

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 126 of 126 April 19, 2010 The light tower shall ha

Strona 32

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 13 of 126 April 19, 2010 CARRYING CAPACITY The GAWR

Strona 33

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 14 of 126 April 19, 2010 TESTING ROAD TEST Road

Strona 34

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 15 of 126 April 19, 2010 2. ALTERNATOR PERFORMANCE

Strona 35

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 16 of 126 April 19, 2010 UL 120/240 VAC CERTIFICATIO

Strona 36

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 17 of 126 April 19, 2010 DIELECTRIC VOLTAGE WITHSTAN

Strona 37

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 18 of 126 April 19, 2010 STRUCTURAL WARRANTY - TEN (

Strona 38

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 19 of 126 April 19, 2010 DELIVERY AND DEMONSTRATION

Strona 39

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 2 of 126 April 19, 2010 LH EXTERIOR REAR COMPARTMENT

Strona 40

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 20 of 126 April 19, 2010 MODEL The chassis shall be

Strona 41

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 21 of 126 April 19, 2010 The method of cab construc

Strona 42

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 22 of 126 April 19, 2010 CAB FRONT FASCIA The front

Strona 43

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 23 of 126 April 19, 2010 CAB PAINT WARRANTY The cab

Strona 44

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 24 of 126 April 19, 2010 LH EXTERIOR COMPARTMENT INT

Strona 45

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 25 of 126 April 19, 2010 APPARATUS WIRING PROVISION

Strona 46

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 26 of 126 April 19, 2010 ENGINE The power plant f

Strona 47

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 27 of 126 April 19, 2010 AUXILIARY ENGINE BRAKE CONT

Strona 48

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 28 of 126 April 19, 2010 ENGINE COOLING SYSTEM The

Strona 49

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 29 of 126 April 19, 2010 ELECTRONIC COOLANT LEVEL IN

Strona 50

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 3 of 126 April 19, 2010 FRONT AXLE WARRANTY ...

Strona 51

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 30 of 126 April 19, 2010 TRANSMISSION The drive t

Strona 52

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 31 of 126 April 19, 2010 TRANSMISSION SHIFT SELECTOR

Strona 53

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 32 of 126 April 19, 2010 DRIVELINE All drivelines

Strona 54

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 33 of 126 April 19, 2010 FRONT AXLE The front axle

Strona 55

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 34 of 126 April 19, 2010 ELECTRONIC POWER STEERING F

Strona 56

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 35 of 126 April 19, 2010 VEHICLE TOP SPEED The to

Strona 57

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 36 of 126 April 19, 2010 TIRE PRESSURE INDICATOR

Strona 58

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 37 of 126 April 19, 2010 BRAKE SYSTEM A rapid bui

Strona 59

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 38 of 126 April 19, 2010 PARK BRAKE Upon applicatio

Strona 60

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 39 of 126 April 19, 2010 AIR SUPPLY LINES A dual

Strona 61

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 4 of 126 April 19, 2010 AIR HORN ...

Strona 62

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 40 of 126 April 19, 2010 FRAME The frame shall co

Strona 63

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 41 of 126 April 19, 2010 FRAME PAINT The frame

Strona 64

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 42 of 126 April 19, 2010 AIR HORN The front bumper

Strona 65

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 43 of 126 April 19, 2010 CAB TILT CONTROL RECEPTACL

Strona 66

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 44 of 126 April 19, 2010 GLASS TINT REAR DOOR LH T

Strona 67

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 45 of 126 April 19, 2010 GLASS UPPER SIDE REAR DOOR

Strona 68

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 46 of 126 April 19, 2010 UNDER CAB INSULATION The

Strona 69

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 47 of 126 April 19, 2010 TRIM CENTER DASH The main

Strona 70

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 48 of 126 April 19, 2010 CAB PAINT INTERIOR DOOR TRI

Strona 71

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 49 of 126 April 19, 2010 SWITCHES RIGHT PANEL The

Strona 72

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 5 of 126 April 19, 2010 SWITCHES CENTER PANEL ...

Strona 73

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 50 of 126 April 19, 2010 SEAT MATERIAL The seats sh

Strona 74

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 51 of 126 April 19, 2010 SEAT OFFICER The officer

Strona 75

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 52 of 126 April 19, 2010 SEAT CREW REAR FACING OUTER

Strona 76

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 53 of 126 April 19, 2010 SEAT COMPARTMENT DOOR FINI

Strona 77

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 54 of 126 April 19, 2010 The mirrors shall be mounte

Strona 78

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 55 of 126 April 19, 2010 BATTERY TRAY The batteries

Strona 79

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 56 of 126 April 19, 2010 ELECTRICAL INLET CONNECTION

Strona 80

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 57 of 126 April 19, 2010 SIDE SCENE LIGHTS The sid

Strona 81

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 58 of 126 April 19, 2010 INBOARD FRONT WARNING LIGH

Strona 82

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 59 of 126 April 19, 2010 ROTO-RAY WARNING LIGHTS SW

Strona 83

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 6 of 126 April 19, 2010 GROUND LIGHTS ...

Strona 84

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 60 of 126 April 19, 2010 One (1) four function gauge

Strona 85

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 61 of 126 April 19, 2010 The instrumentation system

Strona 86

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 62 of 126 April 19, 2010 The instrumentation system

Strona 87

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 63 of 126 April 19, 2010 DIAGNOSTIC SOFTWARE ROLLTE

Strona 88

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 64 of 126 April 19, 2010 CHASSIS MODIFICATIONS LUBR

Strona 89

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 65 of 126 April 19, 2010 ACCIDENT PREVENTION There

Strona 90

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 66 of 126 April 19, 2010  One (1) Hannay EF2016-17

Strona 91

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 67 of 126 April 19, 2010 SEAT BELT WEB LENGTH - CUST

Strona 92

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 68 of 126 April 19, 2010 REAR CAB AREA LAYOUT REAR

Strona 93

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 69 of 126 April 19, 2010 REAR CAB AREA OUTLETS Ther

Strona 94

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 7 of 126 April 19, 2010 SEAT BELT COLOR ...

Strona 95

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 70 of 126 April 19, 2010 OUTLETS AND CIRCUITS The

Strona 96

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 71 of 126 April 19, 2010 EXTERIOR ALUMINUM BODY Th

Strona 97

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 72 of 126 April 19, 2010 BODY MOUNTING The body

Strona 98

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 73 of 126 April 19, 2010 ALUMINUM BODY PAINT SPECIFI

Strona 99

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 74 of 126 April 19, 2010 PAINT FINISH - SINGLE COLOR

Strona 100

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 75 of 126 April 19, 2010 REFLECTIVE STRIPE - CAB S

Strona 101

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 76 of 126 April 19, 2010 REFLECTIVE STRIPE - BODY SI

Strona 102

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 77 of 126 April 19, 2010 UPPER BODY SIDE LETTERING

Strona 103

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 78 of 126 April 19, 2010 EXTERIOR COMPARTMENT DOORS

Strona 104

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 79 of 126 April 19, 2010 BODY HEIGHT MEASUREMENTS T

Strona 105

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 8 of 126 April 19, 2010 ROLL-UP DOOR CONSTRUCTION -

Strona 106

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 80 of 126 April 19, 2010 (7) UPPER BODY COMPARTMENTS

Strona 107

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 81 of 126 April 19, 2010 WALKWAY LIGHTS There shall

Strona 108

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 82 of 126 April 19, 2010 FOLD-DOWN STEP There shall

Strona 109

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 83 of 126 April 19, 2010 STREETSIDE COMPARTMENT - FR

Strona 110

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 84 of 126 April 19, 2010  Air storage module consi

Strona 111

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 85 of 126 April 19, 2010 STREETSIDE COMPARTMENT - AH

Strona 112

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 86 of 126 April 19, 2010  The floor of the compart

Strona 113

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 87 of 126 April 19, 2010 STREETSIDE COMPARTMENT - AB

Strona 114

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 88 of 126 April 19, 2010 STREETSIDE COMPARTMENT - RE

Strona 115

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 89 of 126 April 19, 2010  One (1) Hannay ECR1618-1

Strona 116

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 9 of 126 April 19, 2010 12 VOLT MULTIPLEX CONTROL CE

Strona 117

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 90 of 126 April 19, 2010 CURBSIDE COMPARTMENT - FRON

Strona 118

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 91 of 126 April 19, 2010  One (1) Hannay ECR1618-1

Strona 119

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 92 of 126 April 19, 2010 CURBSIDE COMPARTMENT - AHEA

Strona 120

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 93 of 126 April 19, 2010  There shall be four (4)

Strona 121

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 94 of 126 April 19, 2010 CURBSIDE COMPARTMENT - ABOV

Strona 122

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 95 of 126 April 19, 2010 CURBSIDE COMPARTMENT - REAR

Strona 123

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 96 of 126 April 19, 2010  One (1) Hannay EF2016-17

Strona 124

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 97 of 126 April 19, 2010 ROOF ACCESS STAIRWAY Th

Strona 125

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 98 of 126 April 19, 2010 SIDE BODY PROTECTION - RUB

Strona 126

Windsor-Severence Fire Protection District Heavy Rescue Production Specification SVI #774 Page 99 of 126 April 19, 2010 HEAVY DUTY 100% EXTENSION E

Komentarze do niniejszej Instrukcji

Brak uwag