Strona 1 - Troubleshooting Guide

Bendix™ BlindSpotter® Collision Warning SystemTroubleshooting GuideBendix™ BlindSpotter® Collision Warning SystemBW2860 (Formerly VOTS0032)September 2

Strona 2 - Suggested Tools

Fault Isolation Procedures2-6Power-Up Sequence Test, continued Step C Procedure Condition Action1. Key off.2. Disconnect Operator Display Unit

Strona 3 - Section 1: Introduction

Fault Isolation Procedures2-7Power-Up Sequence Test, continued Step D Procedure Condition Action1. Key off.2. Disconnect sensor harness J2.3.

Strona 4 - Diagnostic Procedure

Fault Isolation Procedures2-8Power-Up Sequence Test, continued Step E Procedure Condition Action1. Key off.2. Disconnect Operator Display Unit

Strona 5 - Electrical Pretest

Operator DisplayAudio TestSymptom Isolation Procedures3-1Operator Display Unit Audible Indictor(Buzzer) Not FunctioningOverviewThis symptom-driven te

Strona 6

3-2Symptom Isolation ProceduresOperator Display Unit Audible Indictor (Buzzer) Not Functioning Step A Procedure Condition Action Step B Procedure

Strona 7 - Electrical Pretest, continued

3-3Operator DisplayAudio TestSymptom Isolation ProceduresOperator Display Unit Audible Indictor (Buzzer) Not Functioning, continued Step C Procedure

Strona 8

Symptom Isolation Procedures3-4Operator Display Unit Audible Indictor (Buzzer) Not Functioning, continued Step D Procedure Condition Action Step V

Strona 9

Symptom Isolation ProceduresSide SensorDetection Test3-5Side Sensor Not Detecting TargetsOverviewThis symptom driven test is performed when the s

Strona 10 - Fault Isolation Procedures

3-6Symptom Isolation ProceduresSide Sensor Not Detecting Targets Step A Procedure Condition Action Step B Procedure Condition Action Step V P

Strona 11 - Power-Up Sequence Test

Symptom Isolation ProceduresSide Sensor ContinuousDetection Test3-7Side Sensor Continuously DetectingTargetsOverviewThis symptom driven test is p

Strona 12

General InformationGeneral WarningsBefore starting a vehicle:1. Sit in the driver’s seat.2. Place the vehicle in neutral.3. Set the parking brake.4

Strona 13 - (Buzzer) Not Functioning

3-8Symptom Isolation ProceduresSide Sensor Continuously Detecting Targets Step A Procedure Condition Action Step B Procedure Condition Action1.

Strona 14 - To Turn Signal Source

Symptom Isolation Procedures3-9Side Sensor ContinuousDetection TestSide Sensor Continuously Detecting Targets, continued Step V Procedure Condition

Strona 15 - Audio Test

Symptom Isolation Procedures3-10Side Sensor Continuously Detecting Targets, continuedThis page left blank intentionally.

Strona 16

A-1AppendixAppendixWiring DiagramsJ2 SODODU PWRODU GNDCOMMPWRGNDSIDE OBJECT DETECTION SENSORP2 SODJ1 ODUODU PWRODU GNDODU COMMTURN SIGNALOPERATORDISPL

Strona 17 - Operator

A-2AppendixJ2J13214562134J1 O D UDISPLAYSENSORJ2 S O D72 INCHES240 INCHES1234563421PW RGN DCO M MOD U P W ROD U G N DRE DBL A C KWH I T EDK G R

Strona 18

A-3AppendixAppendixODU P12.0.702.32.11.02.02.8 BRACKET CANBE BENT± 15°10°FOUR #4 METAL SCREWS4 X 0 .125 THRUMTG. HOLESADHESIVE BACKING1.61.239" ±

Strona 19

A-4Appendix5.65.361.25 MTG. HOLE TOCLEAR CONNECTOR1.380.90.822.04 2.043.53P2 SODP2 SODNOTES:1) USE 3 #10-24 X 1 1/2" S.S.BUTTON HEAD CAP SCREWS F

Strona 20

AppendixAppendixThis page left blank intentionally.

Strona 23 - BlindSpotter

Table of ContentsTable of ContentsSection 1: IntroductionDiagnostic Procedure ... 1-2Sect

Strona 24 - Appendix

901 Cleveland Street • Elyria, OH 44035 • 1-800-AIR-BRAKE • www.bendix.comBW2860 ©2011 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Br

Strona 25

1-2IntroductionDiagnostic ProcedureFollow the fl owchart below for all Bendix™ VORAD® system failures. Perform the tests and procedures as directed by

Strona 26

Fault Isolation Procedures2-1Electrical PretestElectrical PretestOverviewThe pretest verifi es the basic electrical inputs before testing indiv

Strona 27

Fault Isolation Procedures2-2Electrical Pretest Step A Procedure Condition Action1. Key off.2. Inspect starter/battery connections for integrity

Strona 28

Fault Isolation ProceduresElectrical Pretest2-3Electrical Pretest, continued Step C Procedure Condition Action1. Key off.2. Connect negative (-

Strona 29

Fault Isolation Procedures2-4Power-Up Sequence TestOverviewThe failure during the power-up self-check indicates a system failure.DetectionThe

Strona 30

Fault Isolation Procedures2-5Power-Up Sequence TestPower-Up Sequence Test Step A Procedure Condition Action Step B Procedure Condition Action1.