General Information
19
Pretest Procedures
Step Procedure
K 1. VehicleIgnition:Key-ON,Engine-OFF.
2. Measure for J1939 data voltage on pins 5 and 9 of the FLR harness connector.
(J1939 Low to Ground)
a. If the voltage is fluctuating between 0 to 3 volts.
i. Proceed to Step L.
b. If the voltage is a constant 0 volts.
i.TestFailed.Checkforopen/looseconnectionsinthevehicle’sJ1939datalinkharness.
(See Note)
Note: Refer to vehicle OEM repair manual or contact the OEM for more information on the J1939 data link harness.