Using the Gen 4 & 5 Diagnostic Options
NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications 85
Note:
All parameters update continuously to show the most recent
values.
5 Press to return to the CONTINUE BY PRESSING BUTTONS
prompt or to return to the
Select Application
screen.
Tests
Brake-Link offers the following tests:
TEST VALVES
to ensure the modulator valves are working properly
(pg. 85)
.
TEST WARNING LAMP
to ensure the ABS Warning Lamp on the out-
side of the trailer is working properly
(pg. 86)
.
Access all tests
via menu navigation
.
Testing Valves
This test cycles the selected modulator valve.
Note:
The vehicle must be stationary in order to perform this test.
To test selected modulator valve
via menu navigation
:
1 Connect Brake-Link to the tractor or trailer and power-up (see Con-
necting Brake-Link Components, on page 20).
2 Register the ECU (see Register ECU via menu navigation:, on
page 28).
3 Brake-Link presents the
Gen 4/5 Diagnostic
Options
menu; use the
and keys to scroll to
TESTS
and press .
4 Brake-Link displays the
Tests Menu
; use the and keys to
position the cursor on
TEST VALVES
and press .